Carrier Access Access Bank II SNMP Guía de usuario

Busca en linea o descarga Guía de usuario para Redes Carrier Access Access Bank II SNMP. Carrier Access Access Bank II SNMP User`s guide [en] Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 66
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Access Bank II
REMOTE MONITOR USERS GUIDE
5395 Pearl Parkway
Boulder, CO 80301-2490
fax 303-546-9724
http://www.carrieraccess.com
Part Number 770 - 0099
Revision: 1.0 6/99
Vista de pagina 0
1 2 3 4 5 6 ... 65 66

Indice de contenidos

Pagina 1 - Access Bank II

Access Bank IIREMOTE MONITOR USER’S GUIDE5395 Pearl ParkwayBoulder, CO 80301-2490 fax 303-546-9724http://www.carrieraccess.comPart Number 770 - 0099

Pagina 2

viLine Coding: AMI or B8ZS ... ... 3-3CSU On/Off: Ignore or Detect ...

Pagina 3

System Requirements1-1Chapter 1Getting Started1.1 System RequirementsMinimum PC requirements for operating the Remote Monitor management station are:•

Pagina 4

1-21.2 Software Installation1.2.1 Installing Remote MonitorThe Remote Monitor software is designed to operate on the Windows® 95/98/NT environment. It

Pagina 5

Software Overview1-3Remote MonitorSystem Setup T1 SetupData Port SetupConnectionsPerformanceMaintenanceSystem ClockNamesProblem ReportingRemote Manag

Pagina 6 - 0.0.2 Access Bank II SNMP

1-41.4 Connecting the PC Directly to the Access Bank IIThe RS-232 Management cable (provided) is equipped with a male 26-pin D-type subminiature conne

Pagina 7 - 0.0.3 Access Bank II SDSL

Connecting a Modem to the Access Bank II for Remote Access1-51.5 Connecting a Modem to the Access Bank IIfor Remote AccessThe RS-232 Management cable

Pagina 8

1-6To connect the Access Bank II to a modem:1. Connect the PC to a modem using a standard modem cable.2. Connect a modem to the Access Bank II using t

Pagina 9 - CONTENTS

Pull-Down Menus1-7Now that you have successfully loaded and launched the Remote Monitor, you must set it up to work with your Access Bank II. The setu

Pagina 10 - Maintenance

1-81.7 Setting Up Remote MonitorUse the procedures in this section to set up and configure Remote Monitor.1.7.0.1 Selecting the Current ProductThe fir

Pagina 11 - Getting Started

Setting Up Remote Monitor1-9A dialog box appears, asking if you want to save this configuration.3. Select the Yes button to save your configuration.1.

Pagina 13 - Software Overview

1-10The baud rate must be set to match the baud rate of the Access Bank II. The factory default is 9600.3. DO NOT change any settings in the Access Ba

Pagina 14 - 560DQDJHPHQW&DEOH

Setting Up Remote Monitor1-11You will be prompted for a password.4. Enter the correct password and click the Connect button.The default password is c

Pagina 15 - CORPORATION

1-121.7.3 HelpUse Help to initiate the interactive on-line help for the displayed screen. You can activate Help in three ways.• Click on Help, then on

Pagina 16

General Rules and Tips for Using the Remote Monitor1-131.8 General Rules and Tips for Using the Remote MonitorThe Remote Monitor is designed for easy

Pagina 17 - 1.6 Pull-Down Menus

1-14• You can read and send most screens individually, all together, or send just the flagged screens. Sending all screens takes longer, therefore it

Pagina 18 - 1.7 Setting Up Remote Monitor

General Rules and Tips for Using the Remote Monitor1-151.8.2 Screen Flagging• The screen-flagging feature is a tool to help you remember which screens

Pagina 19 - Setting Up Remote Monitor

1-161.8.5 Loading ConfigurationsAny configurations that have been saved from the Remote Monitor can be reloaded. When the Remote Monitor is first load

Pagina 20

System Setup Screens2-1Chapter 2System Setup2.1 System Setup ScreensThe System Setup screens guide you through the naming of the system components, pr

Pagina 21

2-22.1.2 Names ScreenThe Names screen allows you to assign names to the system and the T1, Data, and FX voice ports. Simply type the names you want t

Pagina 22 - 1.7.3 Help

System Setup Screens2-32.1.3 Problem Reporting ScreenTo set up the problem reporting screen, left click in the appropriate box for each alarm listed,

Pagina 23

Copyright© 1999 Carrier Access Corporation. All rights reserved.The information presented in this manual is subject to change without notice and does

Pagina 24

2-42.1.4 The System Clock ScreenUse the System Clock screen to synchronize the Access Bank II clock with the management PC clock, or manually set the

Pagina 25 - 1.8.4 Saving Configurations

System Setup Screens2-52.1.5.1 Configuring Network ParametersSeveral basic settings are required before using the SNMP/Telnet facilities provided by A

Pagina 26 - 1.8.6 Miscellaneous

2-6coldStart Trap and warmStart TrapThese traps are combined in the Access Bank II: A coldStart(0) trap signifies that the sending protocol entity is

Pagina 27 - System Setup

System Setup Screens2-72.1.5.3 Configuring System Group InformationThe values that can be configured are:System NameThe system Name is a string of 1-1

Pagina 29 - System Setup Screens

T1 Setup3-1Chapter 3T1 Setup3.1 T1 SetupThe T1 Setup screen allows you to configure the T1 spans for your installation. T1 Setup fields are used to se

Pagina 30 - 2.1.5 The SNMP Screen

3-23.1.1 System Clock SourceThe T1 Setup screen also allows you to set the system clock source. The clock source is used for tim-ing the transmit side

Pagina 31 - Default Gateway

T1 Definitions3-3T1 Hardware Setup Fields (see definitions below)3.2 T1 DefinitionsT1 Hardware Setup fields are used to set up the T1 network interfac

Pagina 32

3-43.2.6 Line Build Out (LBO):CSU 0 db/DSX (0’-133’), CSU -7.5 dB, CSU -15 dB, CSU -22 dB, DSX (133’-266’), DXS (266’-399’), DSX (399’ - 533’), DSX (5

Pagina 33 - 2.1.5.4 Security

V.35 Data Port Setup4-1Chapter 4Data Port Setup4.1 V.35 Data Port SetupThe Access Bank II control panel contains a V.35 DCE port for connecting to syn

Pagina 35 - T1 Setup

4-24.1.6 Setting the CTS Control OptionCTS Control can be set to force CTS high, force CTS low, follow RTS, or follow CD. Force CTS high is the correc

Pagina 36 - 3.1.2 T1 Hardware Setup

RS-232 Data Port Setup5-1Chapter 5RS-232 Data Port Setup5.1 RS-232 Data Port SetupThe Access Bank II control panel contains a RS-232 data port for con

Pagina 37 - 3.2 T1 Definitions

5-25.1.2 Synchronous Data Rate OptionIf your RS-232 serial device uses a synchronous data rate, select either the 56K or the 64K data rate from the sc

Pagina 38 - 3.2.6 Line Build Out (LBO):

RS-232 Data Port Setup5-35.1.3 Asynchronous Subrate OptionsIf your RS-232 serial device uses asynchronous subrates, select the appropriate options as

Pagina 40

Static Connections6-1Chapter 6Connections6.1 Static ConnectionsThis screen allows the user to configure the voice group and data connectivity. The da

Pagina 41 - RS-232 Data Port Setup

6-26.1.1 Connecting Individual ChannelsTo connect individual channels:1. Click on an origination channel The selected channel turns yellow2. Click on

Pagina 42

Channel Type6-36.1.2 Configuring Contiguous Channels1. Click on the first channel in the group and, holding the mouse button down, drag to the end cha

Pagina 43

6-4Figure 6-1: Channel/Signal Type Screen1. Click on any highlighted channel.You can also click and drag to select a group of contiguous channels.2. C

Pagina 44

The Event Log Screen7-1Chapter 7Performance7.1 The Event Log ScreenThis screen allows the user to request the Alarm/Event history log from the Access

Pagina 45 - Connections

Welcome iRemote MonitorSoftware on PCAccessBank IIAccessBank IImodemmodemRemote MonitorSoftware on PCPSTNAccess Bank IIWelcome to Access Bank II T1 Vo

Pagina 46 - To clear a connection:

7-2Events:Message ExplanationPower Up This is an informational message that logs the time and date that the stytem was powered up.Remote Monitor Login

Pagina 47 - 6.2 Channel Type

The Event Log Screen7-3The following fields are displayed when the alarms are retrieved.High BPV rate for 15 minutes; BPV rate nomi-nal for 15 minutes

Pagina 48

7-4The Screen also displays to the user the total number of Events that have been detected and the total number of events that the Remote Monitor appl

Pagina 49 - Performance

The Event Log Screen7-5Performance information is monitored for Network Loopback Seconds, Loss of Carrier, Alarm Indication Sig-nal, Loss of Frame Cou

Pagina 50 - Message Explanation

7-6Severely Errored Seconds - Errored Seconds (LES) - A Line Errored Second, according to T1M1.3, is a second in which one or more Line Code Violation

Pagina 51 - The Event Log Screen

Testing8-1Chapter 8Maintenance8.1 TestingThe Remote Monitor provides a testing screen to maintain and test the status of the Access Bank II. This prov

Pagina 52 - 7.1.3 T1 History

8-28.1.1.1 LoopbackTo incorporate the internal BERT functionality into the loop, select the BERT Enabled checkbox.The general Network loopbacks are il

Pagina 53 - 7.1.4 Definitions

Testing8-38.1.2 Internal BERT ConfigurationThe Internal Bert Configuration allows you to configure the BERT chip (if enabled) to generate spe-cific pa

Pagina 54

8-48.2 Analog PortsThe 24 available analog ports are associated with the voice channels and plug-in analog cards of the Access Bank II. The analog por

Pagina 55 - Maintenance

Analog Ports8-5• Loop-reverse-battery signaling • Network-provided reverse-battery signaling• E&M signaling• Customer-installation-provided loop-s

Pagina 56 - (e.g., Router)

iiThe Access Bank II Remote Monitor User’s Guide describes how to set up and configure the Access Bank II for first-time basic operation using the MS

Pagina 57

8-6Ringing 0 0Ground-start signaling (FXO-FXS)LCF LO (on hook)0101LCFOLC (off hook)1111Ringing RG (service request)000 0Ground-start signaling with RL

Pagina 58 - 8.2 Analog Ports

Analog Ports8-7The interpretation of the signaling bits for ESF framing are as follows:The following abbreviations are used in this table:LCF - Loop

Pagina 59 - 8.2.1 Update Interval

8-88.3 LEDsThe Access Bank II allows the user, from a remote site, to monitor the signaling state of the Signal Leads for the various data ports that

Pagina 60

LEDs8-98.3.1 System LEDsThe System LEDs portion of the LEDs screen displays the current state of T1 spans 1 and 2, as well as the current status of th

Pagina 61 - Analog Ports

8-108.3.1.1 Definition of Line Status LEDs for T1 Span 1 and T1 Span 2 (first two LEDs)8.3.1.2 Definition of Test LEDs for T1 Span 1 and 2 (third and

Pagina 62 - 8.3 LEDs

DIP Switches8-11Read icon, or pull down the Connection menu and click on Read Current Screen from Unit.

Pagina 64 - 8.4 DIP Switches

Welcomeiii0.0.3 Access Bank II SDSLThe Access Bank II SDSL provides T1 voice and data multiplexing, and is equipped with integrated Channel Service U

Pagina 66

vCONTENTS Access Bank IIAccess Bank II ........... ................iiAccess

Comentarios a estos manuales

Sin comentarios