Carrier Access Network Device Axxius 800 Manual de usuario

Busca en linea o descarga Manual de usuario para Redes Carrier Access Network Device Axxius 800. Carrier Access Network Device Axxius 800 User manual [en] Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - Axxius 800

Axxius 800QUICK START GUIDEPart Number: 002-0151-0006Product Release: 2.2May 2004

Pagina 2

12 Axxius 800 - Release 2.2Quick StartRack MountingTo maintain proper convection cooling, maintain at least 1/2 RU between the Axxius and any other e

Pagina 3 - Safety Information

Axxius 800 - Release 2.2 13 Quick StartCompliant InstallationCompliant InstallationWARNING! ALL TELECOMMUNICATION NETWORK CONNECTIONS MUST USE MINI

Pagina 4

14 Axxius 800 - Release 2.2Quick StartChassis ConnectionsChassis ConnectionsThe following illustrations show all connectors on the rear, as well as t

Pagina 5 - QUICK START GUIDE

Axxius 800 - Release 2.2 15 Quick StartChassis ConnectionsFront of the Axxius 800 - Interface Cardl 10Base-T Ethernet (RJ-48C)l RS-232 Craft Portl

Pagina 6 - Unpacking and Inspection

16 Axxius 800 - Release 2.2Quick StartChassis ConnectionsChassis Ground Connector1. Route wire (#6 or #8 AWG copper) from building ground to lug on A

Pagina 7 - Installation Environment

Axxius 800 - Release 2.2 17 Quick StartChassis ConnectionsPower ConnectionsThere are three power supplies available with the Axxius 800; 24 VDC and 4

Pagina 8 - Assembly of Axxius 800

18 Axxius 800 - Release 2.2Quick StartChassis Connections5. Ensure that no bare wire shows after the wires are installed. 6. Plug connector in the IN

Pagina 9 - Rack Mounting

Axxius 800 - Release 2.2 19 Quick StartChassis ConnectionsExternal Alarm InputsThe external alarm input connector supports 10 alarm inputs and is com

Pagina 10 - Quick Start

20 Axxius 800 - Release 2.2Quick StartChassis ConnectionsVisible and Audible AlarmsThe external alarm connectors are six-pin connectors with two outp

Pagina 11 - Compliant Installation

Axxius 800 - Release 2.2 21 Quick StartChassis ConnectionsBITS Clock 1/BITS Clock 2The external alarm connectors are three-pin wire-wrap connectors.

Pagina 12 - Chassis Connections

Copyright 2004 Carrier Access Corporation. All rights reserved.The information presented in this manual is subject to change without notice and does n

Pagina 13 - Axxius 800 - Release 2.2 15

22 Axxius 800 - Release 2.2Quick StartChassis ConnectionsSlot (1-8) Wire Wrap ConnectorsThe Axxius 800 provides wire wrap connectors for each slot (1

Pagina 14 - Chassis Ground Connector

Axxius 800 - Release 2.2 23 Quick StartChassis ConnectionsWire Wrap Pinout for 4 Wire ServicesWire Wrap Pins T1 Name Description1RX Port 1 Receive Ri

Pagina 15 - Power Connections

24 Axxius 800 - Release 2.2Quick StartChassis ConnectionsWire Wrap Pinout 2 Wire ServicesWire Wrap Pins DescriptionT1 Channel 1 Transmit TipR1 Channe

Pagina 16

Axxius 800 - Release 2.2 25 Quick StartChassis ConnectionsStandard Telco Color CodeCircuit connections are made at the wire wrap connectors. The pino

Pagina 17 - External Alarm Inputs

26 Axxius 800 - Release 2.2Quick StartChassis ConnectionsPair Pin Location Function Color Code15 4015Tip Channel 15 Ring Channel 15Black/SlateSlate/B

Pagina 18 - Visible and Audible Alarms

Axxius 800 - Release 2.2 27 Quick StartConnector PinoutsConnector Pinoutsl Control Panel Interface Cardl OCU-DP (DDS RJ-48S)l Quad T1/ADPCM Cards RJ-

Pagina 19 - BITS Clock 1/BITS Clock 2

28 Axxius 800 - Release 2.2Quick StartConnector PinoutsDS1 Connection PortsThe DS1 connection ports are each equipped with a standard RJ-48C (female)

Pagina 20 - Wire Wrap Connectors

Axxius 800 - Release 2.2 29 Quick StartConnector PinoutsOCU-DP (DDS RJ-48S)The pinout for RJ-48S female is as follows:Note: The above listed function

Pagina 21 - Quick Start

30 Axxius 800 - Release 2.2Quick StartConnector PinoutsQuad T1/ADPCM Cards RJ-48 Connector There are four RJ-48 (female) connectors on the front of t

Pagina 22

Axxius 800 - Release 2.2 31 Quick StartConnector PinoutsV.35 DCE (DB-26)The V.35 DCE data port connection is made at the sub-miniature DB-26 connecto

Pagina 23 - Standard Telco Color Code

PREFACEPrefaceSafety InformationCAUTION! ALWAYS USE CAUTION WHEN INSTALLING TELEPHONE LINES. READ THE CAUTIONS BELOW FOR DETAILS ON SAFETY GUIDELINE

Pagina 24

32 Axxius 800 - Release 2.2Quick StartLEDsLEDsThis section provides details about the LEDs on the Axxius 800.l Control Panel LEDsl DS1 Controller Car

Pagina 25 - Connector Pinouts

Axxius 800 - Release 2.2 33 Quick StartLEDsControl Panel LEDsAlarm LEDsLED State DescriptionCRITICAL Off No critical alarms presentRed Critical alarm

Pagina 26 - DS1 Connection Ports

34 Axxius 800 - Release 2.2Quick StartLEDsEthernet LEDsWhen Status LED is on or flashing:LED State DescriptionSTATUS Off Link DownGreen Link UpFlashi

Pagina 27 - OCU-DP (DDS RJ-48S)

Axxius 800 - Release 2.2 35 Quick StartLEDsDS1 Controller CardThe DS1 Controller has a set of six LEDs. The table below describes each LED.LED State

Pagina 28 - Ethernet (RJ-45C)

36 Axxius 800 - Release 2.2Quick StartLEDsDS3 Controller CardThe DS3 Controller has a set of six LEDs. The table below describes each LED.LED State D

Pagina 29 - V.35 DCE (DB-26)

Axxius 800 - Release 2.2 37 Quick StartLEDs24VDC and 48VDC Power SuppliesBoth power supply cards have identical LEDs, as described in the table below

Pagina 30

38 Axxius 800 - Release 2.2Quick StartLEDsFXO CardEach FXO port on a card has its own LED, described in the table below.ISDN BRI CardsEach ISDN BRI o

Pagina 31 - Control Panel LEDs

Axxius 800 - Release 2.2 39 Quick StartLEDsOCU-DP CardThere are two LEDs for each channel on the OCU-DP card. The function for each LED is listed bel

Pagina 32 - Ethernet LEDs

40 Axxius 800 - Release 2.2Quick StartLEDsSingle Channel POTS CardsThe POTs channel LED (left) status is described in the table below. The second LED

Pagina 33 - DS1 Controller Card

Axxius 800 - Release 2.2 41 Quick StartLEDsQuad DS1/E1, Quad T1, and Quad DS1 ADPCM CardsEach channel on the Quad DS1/E1, Quad T1 and Quad DS1 ADPCM

Pagina 34 - DS3 Controller Card

iv Axxius 800 - Release 2.2PrefaceElectrostatic Discharge (ESD) PrecautionsElectrostatic Discharge (ESD) PrecautionsESD can damage processors, circuit

Pagina 35

42 Axxius 800 - Release 2.2Quick StartLEDsQuad TSR CardThe Quad TSR has 2 LEDs per port.At Power-upNormal OperationPort Set for Ethernet Top LED indi

Pagina 36 - ISDN BRI Cards

Axxius 800 - Release 2.2 43 Quick StartLEDsV.35 CardEach V.35 port has its own LED, as shown in the table below.State DescriptionOff No T1 Assignment

Pagina 37 - OCU-DP Card

44 Axxius 800 - Release 2.2Quick StartLEDsLow Speed Protection CardThe Low Speed Protection card has 10 LEDs, which are defined below.Each channel on

Pagina 38 - Single Channel POTS Cards

Axxius 800 - Release 2.2 45 Quick StartProvision a UnitProvision a Unitl Local using CLI, Telnet, Modem or SNMP (Valet)l Remotely over an in-band DS0

Pagina 39

46 Axxius 800 - Release 2.2Quick StartProvision a UnitBasic System SetupInitial SetupUse the following commands for your initial setup, for further i

Pagina 40 - Quad TSR Card

Axxius 800 - Release 2.2 47 Quick StartProvision a UnitSet Up SecurityUse the following commands to set up the security on the Axxius 800.Set Up a DS

Pagina 41 - V.35 Card

48 Axxius 800 - Release 2.2Quick StartProvision a UnitSet Up a DS1/T1 Use the following commands to set up a DS1. See the set (ds1) command for more

Pagina 42 - Low Speed Protection Card

Axxius 800 - Release 2.2 49 Quick StartProvision a UnitSet Up a DS3Use the following commands for DS3 setup. See the set (ds3) command for more detai

Pagina 43 - Provision a Unit

50 Axxius 800 - Release 2.2Quick StartProvision a UnitSetup DS1 ADPCMBefore configuring the DS1 ADPCM card, there are some basics that need to be con

Pagina 44 - Basic System Setup

Axxius 800 - Release 2.2 51 Quick StartProvision a UnitEstablish a Static Channel ConnectionUse the following commands to establish a static channel

Pagina 45 - Set Up a DS0/Channel

QUICK START GUIDEIn this Guiden Unpacking and Inspection n Installation Environment n Assembly of Axxius 800 n Rack Mountingn Compliant Installationn

Pagina 46 - Set Up a DS1/T1

52 Axxius 800 - Release 2.2Quick StartProvision a UnitSet Up a Single Channel POTS card Use the following commands to set up a POTS card.Change the I

Pagina 47 - Set Up a DS3

Axxius 800 - Release 2.2 53 Quick StartProvision a UnitUpgrade the Axxius 800 SoftwareUse the following commands to determine the Controller software

Pagina 48 - Setup DS1 ADPCM

54 Axxius 800 - Release 2.2Quick StartProvision a UnitBasic Setup of a Protected SystemTo set up a Protected System, the following is required:l Axx

Pagina 49 - Set Up a V.35 Port

8 Axxius 800 - Release 2.2Quick StartUnpacking and InspectionUnpacking and InspectionWARNING! OBSERVE PRECAUTIONS FOR HANDLING ELECTROSTATIC DEVICE

Pagina 50

Axxius 800 - Release 2.2 9 Quick StartInstallation EnvironmentInstallation EnvironmentThe environment in which you are installing the Axxius 800 must

Pagina 51

10 Axxius 800 - Release 2.2Quick StartAssembly of Axxius 800Assembly of Axxius 800The cards should be positioned according to the following guideline

Pagina 52

Axxius 800 - Release 2.2 11 Quick StartRack MountingRack MountingThe Axxius 800 can be mounted on a 19 or 23 inch rack with Carrier Access mounting b

Comentarios a estos manuales