48 Axxius 800 - Release 2.2
Quick Start
Provision a Unit
Set Up a DS1/T1
Use the following commands to set up a DS1. See the set (ds1) command for more
details.
Command Description
set {ds1-addr} up Activate the port.
set {ds1-addr} fdl
{none|t1403}
Set the Facilities Data Link (FDL)
capabilities.
set {ds1-addr} framing
{d4| esf}
Set the framing option for the DS1.
set {ds1-addr} id
{"id-name"}
Set the circuit identification name for the
DS1.
set {ds1-addr} lbo {1-8} Set the line buildout value for the DS1.
set {ds1-addr} linecode
{ami|b8zs}
Set the linecode for the DS1.
set {ds1-addr} loopdetect
{on|off}
Set the detection/reaction to CSU
loopcodes.
set {ds1-addr} threshold
{day|min15} {bes|css|dm|es
|lcv|les|pcv|sefs|ses|uas)
Set default thresholds for the DS1.