Rexroth IndraDrive Introducing the Products 1-5
DOK-INDRV*-FU*********-IB01-EN-P
during firmware download. These errors are not displayed at
the control panel with a diagnostic message number of the
"Fxxxx" pattern, but with a short text. Boot errors and firmware
download errors are separately described in the
documentation "Troubleshooting Guide" (diagnostic message
description).
If the drive controller is in control and an error status is detected, the
execution of a drive error reaction is automatically started. The diagnostic
message number "Fxxxx" flashes on the display of the control panel.
The drive reaction in the case of interface errors and non-fatal errors is
determined in parameter P-0-0119, Best possible deceleration At the
end of each error reaction, the drive is torque-free.
See also "Error Reactions" in chapter "Drive Functions"
Error messages are not cleared automatically but by the following action:
• activating the S-0-0099, C0500 Reset class 1 diagnostics command
- or -
• actuating the "Esc" button on the control panel
If the error status persists the error message is immediately generated
again.
If a drive error occurs while operating with drive enable having been set,
the drive carries out an error reaction. The drive automatically deactivates
itself at the end of each error reaction; in other words, the output stage is
switched off and the drive switches from an energized to a de-energized
state.
To reactivate the drive:
• clear the error message and
• input a positive edge for drive enable again.
The diagnostic message numbers of occurring errors are written to an
error memory. This memory contains the diagnostic message numbers of
the last 50 errors that occurred and the time when they occurred. Errors
caused by a shutdown of the control voltage (e.g. F8070 +24Volt DC
error) are not stored in the error memory.
The diagnostic message numbers in the error memory are mapped to the
P-0-0192, Diagnostic numbers of error memory parameter and can be
displayed by means of the control panel. By means of the "IndraWorks D"
commissioning tool it is possible to display the diagnostic message
numbers and the respective times at which the errors occurred.
Error Reactions of the Drive
Clearing Error Messages
Clearing Error Messages when
Drive Enable Was Set
Error Memory
Comentarios a estos manuales