Carrier Access Network Device Axxius 800 Manual de usuario Pagina 171

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 568
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 170
Axxius 800 - Release 2.2 5-71
CLI Commands
set
set alarms
Use the set alarms to manually set an alarm state for testing.
Syntax: set alarms {critical|major|minor} {off|on}
Example: set alarms critical on
The example set the alarm state of critical on.
{ciritical|major|minor}
{off|on}
set autoexit
Use the set autoexit to set the autoexit feature.
Syntax: set autoexit {off|on}
Example: set autoexit on
The example will enable the auto-exit feature.
{off|on}
critical Sets a critical alarm
major Sets a major alarm.
minor Sets a minor alarm.
off Disables the alarm state.
on Enable the alarm state.
off Turn off the automatic logout option.
on Enable the automatic exit option. Users will be automatically logged off
after 20 minutes of inactivity.
Vista de pagina 170
1 2 ... 166 167 168 169 170 171 172 173 174 175 176 ... 567 568

Comentarios a estos manuales

Sin comentarios