Carrier Access Network Device Axxius 800 Manual de usuario Pagina 62

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 568
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 61
3-6 Axxius 800 - Release 2.2
Electrical Installation and Cabling
Chassis Connections
Chassis Ground Connector
1. Route wire (#6 or #8 AWG copper) from building ground to lug on Axxius 800.
2. Strip insulation off wire end, if necessary.
3. Loosen compression screw until opening is large enough to accept ground wire.
4. Insert ground wire into lug barrel, beneath compression plate and tighten
compression screw.
5. Attach ground lug to chassis
Ground Terminals
Ground Lug
Compression
Screw
Lug Barrel
Vista de pagina 61
1 2 ... 57 58 59 60 61 62 63 64 65 66 67 ... 567 568

Comentarios a estos manuales

Sin comentarios