5-172 Axxius 800 - Release 2.2
CLI Commands
set
set (v54)
Use the set (v54) command to setup V.54 Loopback Test Parameters. The command specifies
the range of channels within that card, and the setting to apply.
Syntax: set {v54-addr} v54 {setting} [off|on] [n] [nnn]
Example: set 6:1 v54 equipment clear
The example will clear the loop test counter on the V.54 card in slot 6, port 1.
{v54-addr}
In the form of {slot:port}.
{setting}
slot Slot number (1-8) of the Axxius chassis where the V.35/54 card is located
port Port number or range.
equipment Set the V.54 Equipment (Tx) parameters:
address
Syntax: set {v54-addr} v54 equipment address {nnn}
Set V.54 loop test address [nnn]
Set the address to be tested.
[nnn] {nnn} must be one of the following:
0 - 255.1, 3, 5, 7, 9, 11, 13, 15,17, 19, 21, 23, 25, 27, 29, 31, 37, 39,
43, 45, 47, 51, 53, 55, 59, 61, 63, 85, 87, 91, 95, 111, 119, 127, 255
(255 disables). See chart below.
clear
Syntax: set{v54-addr} v54 equipment clear
Clear the bit error rate counters during BER test
ignoreack
Syntax: set{v54-addr} v54 equipment ignoreack
{off|on}
Ignore V.54 ACK check [off|on]
Ignore acknowledge from remote equipment. This allows potential
testing with non-compliant equipment by ignoring the acknowledge
phase. WARNING: When choosing this option, the V.35 card
will no longer be compliant with the V.54 specification. Use for
debug purposes only.
loopdown
Syntax: set{v54-addr} v54 equipment loopdown
Stop the test sequence
loopup
Syntax: set{v54-addr} v54 equipment loopup
Start the test sequence