Carrier Access Network Device Axxius 800 Manual de usuario Pagina 180

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 568
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 179
5-80 Axxius 800 - Release 2.2
CLI Commands
set
threshold
Set default thresholds for a DS1. Defaults for all are 0.
day Set threshold for a daily interval
bes Bursty errored seconds range: 0 - 86400
css Controlled slip seconds range: 0 - 86400
dm Degraded minutes range: 0 - 1440
es Errored seconds range: 0 - 86400
lcv Line code violations range: 0 - 133401600
les Line errored seconds range: 0 - 86400
pcv Path code violations range: 0 - 133401600
sefs Severely errored frame seconds range: 0 - 86400
ses Severely errored seconds range: 0 - 86400
uas
Unavailable seconds range: 0 - 86400
min15 Set threshold for a 15 minute interval
bes Bursty errored seconds range: 0 - 900
css Controlled slip seconds range: 0 - 900
dm Degraded minutes range: 0 - 15
es Errored seconds range: 0 - 900
lcv Line code violations range: 0 - 1389600
les Line errored seconds range: 0 - 900
pcv Path code violations range: 0 - 1389600
sefs Severely errored frame seconds range: 0 - 900
ses Severely errored seconds range: 0 - 900
uas
Unavailable seconds range: 0 - 900
up Set the DS1 as In-Service. Enables alarm reporting (and LED) for the
port specified
Vista de pagina 179
1 2 ... 175 176 177 178 179 180 181 182 183 184 185 ... 567 568

Comentarios a estos manuales