Axxius 800 - Release 2.2 6-7
DS1 Controller Card
Technical Specifications
Alarms
l Three visible alarm outputs, critical, major and minor
l Three audible alarm outputs, critical, major and minor
l Alarm Cut-Off for audible alarm outputs
l Ten external alarm inputs (user definable)
l Alarm contacts accessible from external alarm connector
l All alarms are logged in an event log
l Loss of power triggers minor alarm
l Generates SNMP traps for alarming (MIB objects)
Testing and Diagnostics
l Standard T1 line and payload loopbacks
l Local loopback
l T1.231 performance history
Power Consumption
l 6 W maximum
Environment
In addition to the systems environment requirements, the following applies to the
DS1 Controller card. For additional information see Installation Environment” on
page 2-3.
l Operating temperature range of the DS1 Controller card: -40° to 149° F
(-40° to 65° C)
Physical
l Dimensions: 3.5 in. (H) x 0.75 in. (W) x 11.25 in. (D)
8.9 cm (H) x 1.9 cm (W) x 28.6 cm (D)
l Weight: 10.2 oz. (0.29 kg)