Axxius 800 - Release 2.2 C-13
Loopback Tests
DS1 Loopbacks
errored seconds: 0 0
sev. errored frame seconds: 0 0
line errored seconds: 0 0
controlled slip seconds: 0 0
bursty errored seconds: 0 0
degraded minutes: 0 0
total linecode violations: 0 0
total pathcode violations: 0 0
Disable Equipment Loopback
> set 5:1 equipment loopdown
OK
View Status of Loopback
> show 5:1
SLOT 5:
Settings for DS1 1:
Circuit ID: CAC DS1# 5:1
Up/Down: UP
Framing: ESF
Line Coding: B8ZS
Line Build Out: DSX-1 EQUALIZATION FOR 0-133 ft.
(CSU 0dB)
Loop Code Detection: ON
Loopback: OFF
FDL Type: None
Performance Threshold Settings 15 min. 1 day
unavailable seconds: 0 0
severely errored seconds: 0 0
errored seconds: 0 0
sev. errored frame seconds: 0 0
line errored seconds: 0 0
controlled slip seconds: 0 0
bursty errored seconds: 0 0
degraded minutes: 0 0
total linecode violations: 0 0
total pathcode violations: 0 0