C-12 Axxius 800 - Release 2.2
Loopback Tests
DS1 Loopbacks
DS1 Equipment Loop
Note: Quad T1 LED flashes green during equipment loop.
Enable Equipment Loopback
Where a Quad T1 card is in slot 5.
> set 5:1 equipment loopup
OK
View Status of Loopback
> show 5:1
SLOT 5:
Settings for DS1 1:
Circuit ID: CAC DS1# 5:1
Up/Down: UP
Framing: ESF
Line Coding: B8ZS
Line Build Out: DSX-1 EQUALIZATION FOR 0-133 ft.
(CSU 0dB)
Loop Code Detection: ON
Loopback: EQUIPMENT
FDL Type: None
Performance Threshold Settings 15 min. 1 day
unavailable seconds: 0 0
severely errored seconds: 0 0
T1
Axxius
Local
DTE
Local
DCE
V.35
DS1
Network
Loops DS1 as shown
Vista de pagina 521